Evaluation of the Inelastic Behavior Factor R for Reinforced Concrete Elevated Water Tank Samples

Authors

  • عصام ناصر قسم الهندسة الإنشائية - الهندسة المدنية - جامعة اللاذقية
  • بسام حويجة قسم الهندسة الإنشائية - الهندسة المدنية - جامعة اللاذقية
  • رهام ابوبالا قسم الهندسة الإنشائية - الهندسة المدنية - جامعة اللاذقية

Keywords:

Nonlinear Behavior Factor - Elevated Water Tanks – Nonlinear Analysis – Housner Model.

Abstract

Seismic design of structures is fundamentally based on the capacity to absorb and dissipate earthquake – induced energy. This is particularly critical for elevated water tanks, given their essential role in ensuring the continuity of water supply for domestic use purpose following seismic events.

This study presents an analytical investigation of reinforced concrete elevated water tanks aimed at evaluating the inelastic behavior factor ( R ), which reduces elastic base shear to design levels based on the structural ductility and overstrength. Nonlinear dynamic analyses were conducted using ABAQUS on two configurations with circular and rectangular basins, each with a capacity of and supported by a frame system. The hydrodynamic effects were modeled using the HOUSNER approach.The R factor was evaluated using three methodologies: force-displacement, maximum acceleration, and hysteretic energy dissipation.

The results show that hysteretic energy dissipation methodology provides more reliable estimate for elevated water tanks, considering their structural behavior, and the obtaind values are consistent with those specified in Appendix (7) of the Syrian code (Appendix 7 for the Syrian code,2022).

Downloads

Published

2026-10-29